• Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic
  • Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic
  • Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic
  • Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic
  • Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic
  • Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic

Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic

Customized: Non Customized/Customized
Certification: ISO, CE
Condition: New
Usage: Fracture Fixation
Using Site: Waist, Tibial, Radius,Femoral,Humeral
Type: External Fixator
Samples:
US$ 102/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Trading Company
  • Overview
  • Detailed Photos
  • Related Products
  • Company Profile
  • Our Equipment
  • Certifications
  • OUR TEAM
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
external fixator
Application
Orthopedic
Group
Adult
Material
Alumium
Transport Package
Sterilized, PE Bag, Carton Package
Specification
Customizable
Trademark
Gather
Origin
Jiangsu
HS Code
9021100090
Production Capacity
1000pieces/Week

Product Description


Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic

Physicians have been using external fixation to treat fractures for more than 2000 years after being first described by Hippocrates as a way to immobilize the fracture while preserving soft tissue integrity. The fixator design and biomechanics have changed dramatically over the years, but the principles remain the same. The primary goal of external fixation is to maintain the length, alignment, and rotation of the fracture. External fixation can serve as provisional fixation or definitive fixation purposes. Both methods can be performed in conjunction with partial internal fixation if necessary. It is important for orthopedic surgeons at a trauma center to be familiar with the techniques and principles of external fixation for various fractures of the upper extremity, lower extremity, and pelvis.
 

Fracture healing physiology largely depends on the mode of fixation and level of stability. With absolute fracture stability such as compression plating, the bone will undergo primary intramembranous bone healing. On the other hand, relative fracture stability, such as external fixation, results in secondary enchondral bone healing. There are also several ways to alter the external fixation construct to make the fracture more or less stable.

 

Detailed Photos

 

 

Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical OrthopedicPelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic

 

 

Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical OrthopedicPelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic

Related Products

Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic

Company Profile

Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical OrthopedicPelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic

Our Equipment

Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic

Certifications

Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic

OUR TEAM

Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic

Packaging & Shipping

Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic

FAQ

Q1. Can I have a sample order ?

A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.

 

Q2. What about the lead time?

A: 3-5 days for Sample preparing , for mass production need to be confirmed .

 

Q3. Can you accept customized ?

A: Yes , we have complete design and drawing department and CNC machine , we can complete high-precision customized services.

 

Q4. How do you ship the goods and how long does it take to arrive?

A: Ship by DHL, UPS, FedEx or TNT. It takes 3-5 days to arrive. Professional shipping services can meet your needs for customs clearance..

 

Q5. How to proceed an order ?

A: Firstly let us know your requirements or application.

Secondly We quote according to your requirements or our suggestions.

Thirdly customer confirms the samples and places deposit for formal order.

Fourthly We arrange the production.

 

Q6. Is it OK to print my logo ?

A: Yes. Please inform us formally before our production.

 

Q7: Do you offer guarantee for the products?

A: Yes, we offer 3 years warranty to our products.

 

Q8: If there is any payment terms ?

A: Depend on our cooperation , we can consider and give

Pelvic Trauma Fixation Type External Fixator Tibia Fracture Medical Orthopedic

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Trading Company
Registered Capital
1.48 Million USD
Plant Area
120 square meters